Pulse Thermography

Applies a controlled heat pulse and records the thermal response to find near-surface defects.

Method code
Pulse thermography
Materials
Composites and bonded structures
Product forms
Rudder side panels, laminates, repair patches
Standards
ASTM E2582, AD 2013-0302, AD 2014-0033

Pulse thermography heats the surface with a single controlled flash and records the whole cooling curve, which turns a qualitative picture into a measured, repeatable result.

How it works

A short, high energy flash deposits heat across the surface in a few milliseconds. An infrared camera then records the cooling at every pixel, and the resulting curves are processed rather than simply viewed. Because the input is a defined pulse and the whole decay is captured, the technique discriminates depth better than a steady heating approach, and gives a result that can be repeated on the same structure later and compared.

What it detects

Disbonds, delaminations, water ingress and core damage in composite and bonded structures, with better depth discrimination and repeatability than general thermography offers.

Typical applications

Airbus rudder side panel inspection carried out in response to airworthiness directives AD 2013-0302 and AD 2014-0033, and other composite structures where a recorded and repeatable result is required.

Ready when you are

Talk to our inspection team

Tell us what needs inspecting and we will tell you how we would approach it, what it will cost and how quickly we can be there. No obligation, and you speak to an engineer rather than a call centre.

Aircraft on ground? The AOG line is answered around the clock, every day of the year.

The wider group

Our partner companies

Morgan Ward sits within a group of specialist businesses covering calibration, inspection training and NDT recruitment across the UK, Malta and beyond.